Offer
Provide additional details about the offer you're running.
The Victron Energy Smart BatteryProtect 48V 100A protects a battery bank against excessive discharge by disconnecting non-essential DC loads before the battery voltage falls to a damaging level. It can also preserve enough battery capacity to start an engine and can be configured to function as a system on/off switch.
Built-in Bluetooth allows the connection and disconnection voltage thresholds to be programmed through the VictronConnect app. Nine predefined voltage profiles can also be selected using the programming pin. VictronConnect Instant Readout displays warnings, alarms and errors directly from the device list for quick system diagnostics.
Key Features:
The Smart BatteryProtect is a unidirectional device. Current can flow only from the IN terminal to the OUT terminal. It can control current going to a load or current coming from a charger, but it cannot handle both directions simultaneously. Correct installation orientation is essential.
This unit is suitable for protecting 48V battery banks in marine, vehicle, off-grid, backup and industrial DC systems. Its high-current capacity, programmable thresholds and remote monitoring features make it a practical alternative to using a conventional high-current relay for battery protection.
Technical Specifications:
| Manufacturer | Victron Energy |
| Model | Smart BatteryProtect 48V 100A |
| Manufacturer Part Number | BPR110048000 |
| Nominal System Voltage | 48V DC |
| Operating-Voltage Range | 24–70V DC |
| Maximum Continuous Load Current | 100A |
| Peak Current | 250A |
| Default Disconnect Voltage | 42V DC |
| Default Reconnect Voltage | 48V DC |
| Overvoltage Load Disconnect | Above 64V DC |
| Current Direction | Unidirectional, from IN to OUT |
| Switching Technology | MOSFET; no electromechanical relay |
| Wireless Communication | Built-in Bluetooth |
| Alarm Output Delay | 12 seconds |
| Maximum Alarm-Output Load | 50mA; short-circuit protected |
| Load Disconnect Delay | 90 seconds; immediate when triggered by a VE.Bus BMS |
| Load Reconnect Delay | 30 seconds after reaching the programmed reconnect voltage |
| Current Consumption with Bluetooth On | 1.9mA while on / 1.7mA while off or after low-voltage shutdown |
| Temperature and Load Rating | Full 100A load from -40°F to 104°F; up to 60A at 122°F |
| Electronics Protection Rating | IP67, potted electronics |
| Connection Protection Rating | IP00; terminals are exposed and require appropriate installation protection |
| Power Connections | M8 |
| Recommended Mounting Torque | 9Nm |
| Dimensions (H × W × D) | 2.5 × 4.9 × 4.8in (62 × 123 × 120mm) |
| Weight | 1.8lb (0.8kg) |